RECREATIONAL VEHICLE INVERTER / CHARGER
Designed Specifically for recreational vehicles
The Trace Legend Series II has set a new industry standard for performance, advanced features and user friendly operation. Flexible enough to meet the most sophisticated users needs and yet so simple to operate - set it and forget it. There are no dip switches or jumpers to set. All features are accessible via a menu driven remote display. Permanent memory stores your menu selections even if power is disconnected. It never needs reprogramming unless your power needs change.
High performance, high surge inverter power, three stage battery charger with temperature compensation, automatic shore power black-out protection, full feature remote controls with meters and battery fuel gauge.
Standard Features:
Optional Remote Controls:
Specifications:
L2012
L2512
L3012
Continuous Output Power @ 25C
2000VA
2500VA
3000VA
Continuous AC Output Current @ 25C
16.6 amps
20.8 amps
25 amps
Efficiency (peak)
94%
94%
94%
DC Requirements:
Normal Input Voltage
12VDC
12VDC
12VDC
Input DC Voltage Range
10.2 - 15.5 VDC
10.2 - 15.5 VDC
10.2 - 15.5 VDC
Search mode
0.055 amps
0.070 amps
0.080 amps
On Mode (no load - idle)
0.55 amps (6.3 watts)
0.60 amps (7.2 watts)
0.650 amps (7.9 watts)
At Full Rated Power
200 amps
250 amps
300 amps
Short Circuit Output
600 amps
800 amps
900 amps
Automatic Low Battery Protection
10.9 VDC or defeated
10.9 VDC or defeated
10.9 VDC or defeated
Adjustable Battery Charge Rate
10-100 amps
10-120 amps
10-140 amps
Minimum Recommended DC
Fuse Size300 amps DC
300 amps DC
400 amps DC
Minimum Recommended DC
Cabling#4/0 AWG
#4/0 AWG
#4/0 AWG
AC Output Characteristics
Voltage Regulation - Max.
+/- 5%
Voltage Regulation - Typical
+/- 2.5%
Output Waveform
modified sine wave
Power Factor Allowed
0 to +1
Frequency Regulation
60 Hz +/- .04%
Standard Output Voltage
120 VAC RMS
Adjustable AC Load Sensing
5 to 40 Watts AC
Automatic Transfer Relay
30 amps AC at 120 VAC
Battery Charger Characteristics
Charging Profiles
Vented lead acid or sealed lead acid (Gel Cel)
Charging Process
Three stage charging process (Bulk, Absorption, & Float)
Battery Temperature Compensation
with optional BTS sensor
Options
Remote Control
RC6: Simple LED Bargraph DC voltage / ammeter with ON/OFF switch
RC7: Full function remote control with LCD display and status LEDs.
Battery Temperature Sensor (BTS)
BTS Sensor with 15 or 35 foot cable (plug in)
DC Fuse Block (TFB)
Class T fuse with holder and protective cover - 300 amp, 400 amp sizes.
Environmental
Forced Air Cooling
Variable speed brushless DC fan.
Specified Temp. Range
32F to +100F (0C to +40C) (will meet specified tolerances)
Allowed Temp. Range
-40F to +140F (-40C to +60C) (may not meet specified tolerances)
Non-operating Temp. Compensation
-67F to +167F (-55C to +75C)
Enclosure Type
Indoor, ventilated, steel chassis with powdercoated finish.
Dimensions - inverter only
13.125" x 7.25" x 15.50"
Mounting
Shelf mount Only
Unit Weight
45 lbs. (20.5kg)
50 lbs (22.7kg)
60 lbs (27.2kg)
NOTE: All specifications are subject to change without notice.
Adjustments required RC7 Remote Control.


Power VS Time charge for Legend Series II
Charging Profile

Legend Series II Efficiency Chart